Brocade Core Router CLI Notes
Overview
This ICX6610 network switch is capable of acting as a core router for a large site in the Mesh.
It provides 802.3at PoE+ power to all of its 48 ports (or 24 ports on the ICX6610-24P), has 10 SFP+ 10G ports on the front, 2 QSFP+ 40G ports on the back, and then 2 QSFP+ ports that can only operate as 4x10G SFP+ breakout cables.
The 40G ports can be used to connect a hub to dark fiber running to a data center, which is how the Juniper QFX5100-48S at Grand St is set up. The QSFP+ to 4x 10G SFP+ ports can be used with Direct Attach Cables (DACs) to connect to other rackmount gear, such as a Ubiquiti PON OLT for in-building fiber to the apartment. The SFP+ ports on the front can be used in a similar way to the Mikrotik CCR2004, connecting fiber runs to a roof rack, Mikrotik netPower 16P, Ubiquiti Wave APs, Siklu EtherHaul 8010FX, etc. The PoE ports can be used to power any device compatible with 802.3af/at active PoE, such as "rabbit ear" Ubiquiti AC Mesh Access Points (APs), IP cameras, IP phones, and even Ubiquiti PoE converters to provide passive 24V PoE.
The switch also has advanced L3 functionality and can also perform routing duties. It supports OSPF, DHCP Server, VLANs, and more.
It is configured either with a DB9/RS232/Serial Console Cable (a Cisco cable works), or via SSH. There is also a Web UI with limited functionality.
The switch has an 800MHz PowerPC processor, 512MB RAM, and runs FastIron OS, which is very similar to Cisco's IOS. The latest software update for the ICX6610 as of 2024Q1 was 2020-04-29 with release 08.0.30u
. A used ICX6610-48P was purchased off Ebay for $150 in 2024Q1 for Olmsted NN584, its stock serial number is BXK2526J0YG
and its stock software was 08.0.30t
(from 2019-02-18) with boot monitor 10.1.00T7f5
Initial Setup - Firmware and License
- The original instructions can be found here and here with a Youtube version here
- This initial setup requires a TFTP server to be running, serving the files needed for these steps. Assume for this example that the TFTP server's IP is 10.97.227.164
- Connect the Management RJ45 port in the back of the switch to the network the TFTP server is connected to. Also connect the Console cable and get the
screen
orminicom
console session going, ready to receive printout from the switch while it boots - Connect power while hitting
B
on the console keyboard to interrupt the boot process and enter the Boot Monitor prompt. If the line is filled withbbb
, press Enter to clear to get to a new line
ICX Boot Code Version 10.1.00 (grz10100)
Enter 'a' to stop at memory test
Enter 'b' to stop at boot monitor
***** Interrupted by entering 'b' *****
.BOOT INFO: load monitor from boot flash, cksum = 71f1
BOOT INFO: verify flash files.......
Monitor>bbb
Not found in command table, 'bbb'
Monitor>
- Give the switch a static IP on the same network as the TFTP server. In this example, the switch is 10.97.227.165 so it can connect to the TFTP server 10.97.227.164
Monitor>ip address 10.97.227.165
IP address = 10.97.227.165
IP subnet mask = 255.255.255.0
Monitor>
- Update the Boot Monitor and the main software using TFTP, first with
copy tftp flash 10.97.227.164 ICX6610-FCX/grz10100.bin boot
and then withcopy tftp flash 10.97.227.164 ICX6610-FCX/FCXR08030u.bin primary
Monitor>copy tftp flash 10.97.227.164 ICX6610-FCX/grz10100.bin boot
Loading image from Tftp
............................................Done
Programming boot flash, please wait..
Erasing....
Writing
Done
Monitor>copy tftp flash 10.97.227.164 ICX6610-FCX/FCXR08030u.bin primary
.......................................Done
.Monitor>
- Erase the config (reset to factory defaults) with
factory set-default
and theny
Monitor>factory set-default
This command will remove configuration and keys detail.
Do you want to continue? (Y/N) y
Done.
Monitor>
- Finally, reboot the switch to apply the fresh software and settings with
reset
. This will take a couple minutes.
Monitor>reset
$
ICX Boot Code Version 10.1.00 (grz10100)
Enter 'a' to stop at memory test
Enter 'b' to stop at boot monitor
.BOOT INFO: load monitor from boot flash, cksum = 71f1
BOOT INFO: verify flash files......
BOOT INFO: load image from primary copy...
- After a couple minutes, the console may be printing repeated
TFTP session timed out
lines. PressENTER
to get past the messages and to a prompt.
PoE Info: PoE module 1 of Unit 1 initialization is done.
TFTP session timed out
TFTP session timed out
TFTP session timed out
ICX6610-48P Router>
- Enter the configuration mode with
enable
and thenconfigure terminal
. Then disable the DHCP client withip dhcp-client disable
ICX6610-48P Router>
ICX6610-48P Router>enable
No password has been assigned yet...
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#TFTP session timed out
ICX6610-48P Router(config)#ip dhcp-client disable
ICX6610-48P Router(config)#
- Now give the switch a static IP address. All ports are VLAN1 by default. Give VLAN1 its own virtual interface, and then assign that virtual interface an IP address (the same as before). Then write the memory to save these settings as permanent
ICX6610-48P Router(config)#vlan 1
ICX6610-48P Router(config-vlan-1)#router-interface ve 1
ICX6610-48P Router(config-vlan-1)#exit
ICX6610-48P Router(config)#interface ve 1
ICX6610-48P Router(config-vif-1)#ip address 10.97.227.165/24
ICX6610-48P Router(config-vif-1)#exit
ICX6610-48P Router(config)#write memory
Write startup-config done.
ICX6610-48P Router(config)#exit
ICX6610-48P Router#
- Disconnect the Ethernet cable from the management port and move it to any of the ports on the front of the switch. Otherwise, the TFTP connection won't work in the next steps
- Now update the PoE module firmware (one per switch, this is not related to the power supplies), again using the TFTP server, with
inline power install-firmware stack-unit 1 tftp 10.97.227.164 ICX6610-FCX/fcx_poeplus_02.1.0.b004.fw
ICX6610-48P Router#inline power install-firmware stack-unit 1 tftp 10.97.227.164 ICX6610-FCX/fcx_poeplus_02.1.0.b004.fw
ICX6610-48P Router#Flash Memory Write (8192 bytes per dot) ...........
tftp download successful file name = poe-fw
Sending PoE Firmware to Unit 1.
ICX6610-48P Router#
- Use
show log
to monitor the update process, which may take 10 minutes.
ICX6610-48P Router#show log
Syslog logging: enabled ( 0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 14 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
00 days 00h02m39s:I:System: Stack unit 1 POE Power supply 1 with 748000 mwatts capacity is up
00 days 00h02m39s:I:System: Stack unit 1 POE Power supply 2 with 748000 mwatts capacity is up
Dynamic Log Buffer (50 lines):
00 days 00h06m00s:I:System: U1-MSG: PoE Info: Firmware Download on slot 1.....40 percent completed.
00 days 00h05m25s:I:System: U1-MSG: PoE Info: Firmware Download on slot 1.....30 percent completed.
- Reboot using
reload
once the firmware is updated. The switch won't let the reboot occur until the update is complete
ICX6610-48P Router#reload
Are you sure? (enter 'y' or 'n'): Rebooting(0)...
y
ICX6610-48P Router#*
$
ICX Boot Code Version 10.1.00 (grz10100)
Enter 'a' to stop at memory test
Enter 'b' to stop at boot monitor
- Now get into privileged mode with
enable
, then update the serial number in the software to match the license that will be applied next, and reboot
ICX6610-48P Router>enable
No password has been assigned yet...
ICX6610-48P Router#hw pid-prom serial 2ax5o2jk68e
ICX6610-48P Router#hw pid-prom clear-sw-lid
ICX6610-48P Router#reload
Are you sure? (enter 'y' or 'n'): Rebooting(0)...
y
ICX6610-48P Router#*
$
ICX Boot Code Version 10.1.00 (grz10100)
- Now re-enter the privileged mode and use TFTP to copy over the license files
ICX6610-48P Router>enable
No password has been assigned yet...
ICX6610-48P Router#copy tftp license 10.97.227.164 ICX6610-FCX/1-6610-ports.xml unit 1
ICX6610-48P Router#Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
ICX6610-48P Router#copy tftp license 10.97.227.164 ICX6610-FCX/2-6610-adv.xml unit 1
ICX6610-48P Router#Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
copy tftp license 10.97.227.164 ICX6610-FCX/3-6610-macsec.xml unit 1
ICX6610-48P Router#Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
- Use
show license
to confirm that the license has been applied and the 10G ports are usable
ICX6610-48P Router#show license
Index Lic Mode Lic Name Lid/Serial No Lic Type Status Lic Period Lic Capacity
Stack unit 1:
1 Node Lock ICX6610-10G-LIC-POD H4CKTH3PLN8 Normal Active Unlimited 8
2 Node Lock ICX6610-ADV-LIC-SW H4CKTH3PLN8 Normal Active Unlimited 1
3 Node Lock ICX-MACSEC-LIC H4CKTH3PLN8 Normal Active Unlimited 1
ICX6610-48P Router#
- Finally, run
write memory
to save all the settings so far as permanent
ICX6610-48P Router#write memory
ICX6610-48P Router#Flash Memory Write <8192 bytes per dot> .
Copy Done.
ICX6610-48P Router#
Initial Setup - System
- Enable SSH access to the management command line by first generating an RSA keypair. Then create a username and password. Then enable that username and password to allow logins via SSH and the Web UI. Also disable the Telnet server. Then save the settings
- Optionally,
enable aaa console
can be added to force a password on the console. JohnB skipped this step since the passwords are all placeholders anyway
- Optionally,
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#crypto key zeroize
RSA Key pair not found
ICX6610-48P Router(config)#crypto key generate rsa modulus 2048
ICX6610-48P Router(config)#
Creating RSA key pair, please wait...
RSA Key pair is successfully created
ICX6610-48P Router(config)#username root password <mesh password here>
ICX6610-48P Router(config)#aaa authentication login default local
ICX6610-48P Router(config)#aaa authentication web default local
ICX6610-48P Router(config)#no telnet server
ICX6610-48P Router(config)#write mem
- To actually connect via SSH, some special arguments need to be passed in to support the key exchange and host key algorithms supported by the switch
-
ssh -oKexAlgorithms=+diffie-hellman-group1-sha1 -oHostKeyAlgorithms=+ssh-rsa root@10.97.227.165
- https://unix.stackexchange.com/questions/402746/ssh-unable-to-negotiate-no-matching-key-exchange-method-found
- https://askubuntu.com/questions/836048/ssh-returns-no-matching-host-key-type-found-their-offer-ssh-dss
-
- The hostname is by default
ICX6610-48P Router
as seen in the first part of every command line. This can be changed withhostname <newname>
. For Olmsted, this has been changed tohostname nycmesh-nn584-brocade-poe-switch
or possiblyhostname nycmesh-nn584-brocade-core
- To configure the switch's DNS server, https://wiki.mesh.nycmesh.net/link/92 shows that
10.10.10.10
is the server of choice for the Mesh.
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#ip dns server-address 10.10.10.10
- TODO: To configure the default route for the switch, the
ip route
command can be run. But this may conflict with the OSPF routing table according to Olivier
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#ip route 0.0.0.0/0 10.69.69.69
- To configure NTP, set Daylight Savings to be enabled, pick the time zone, enter the NTP configuration, disable serving NTP to clients, pick the IP addresses of the NTP servers to source from (maximum support for 8 IPs) and then exit and save
- NOTE that
no ntp
will reset the configuration - The IP for NTP is 10.10.10.123
- NOTE that
clock summer-time
clock timezone gmt GMT-05
ntp
disable serve
server 10.10.10.123
exit
- The NTP status can be checked with
show ntp associations
andshow ntp status
- To enable SNMPv2 for statistics gathering, run
snmp-server community public ro
- To enable optical module monitoring, run the
optical monitor
command
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#optical-monitor
Initial Setup - Ports
- To use the 40G ports on the back of the switch, they need to be removed from the switch stacking configuration
- With its factory settings
show run
will showstack-trunk
lines claiming usage of the 40G ports in module 2 (the last two lines)
stack unit 1
module 1 icx6610-48-port-management-module
module 2 icx6610-qsfp-10-port-160g-module
module 3 icx6610-8-port-10g-dual-mode-module
stack-trunk 1/2/1 to 1/2/2
stack-trunk 1/2/6 to 1/2/7
!
- Go into privileged and then configuration mode and remove the
stack-trunk
settings, and disable the stack. Then save the settings withwrite mem
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#stack unit 1
ICX6610-48P Router(config-unit-1)#no stack-trunk 1/2/1 to 1/2/2
ICX6610-48P Router(config-unit-1)#no stack-trunk 1/2/6 to 1/2/7
ICX6610-48P Router(config-unit-1)#stack disable
ICX6610-48P Router(config-unit-1)#exit
ICX6610-48P Router(config)#write mem
- Now use
show run
again to confirm the configuration has changed
ICX6610-48P Router(config)#show run
Current configuration:
!
ver 08.0.30uT7f3
!
stack unit 1st
module 1 icx6610-48p-poe-port-management-module
module 2 icx6610-qsfp-10-port-160g-module
module 3 icx6610-8-port-10g-dual-mode-module
stack disable
!
- Next, configure the 8 SFP+ ports to operate explicitly at 10G speeds with
speed-duplex
commands. The interfaces can all be configured at the same time. Note that if a module is installed that is 1G and not 10G, an error will be shown.- TODO: Unclear if setting
speed-duplex auto
instead ofspeed-duplex 10g-full
would also work fine. If not, setting the 1G interfaces tospeed-duplex 1000-full
should work, as per the command reference PDF. Alternatively, theno speed-duplex
will reset the interface to its default settings
- TODO: Unclear if setting
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#interface ethernet 1/3/1 to 1/3/8
ICX6610-48P Router(config-mif-1/3/1-1/3/8)#speed-duplex 10g-full
INFO: 1/3/3: optics <-> speed mismatch. Replace with SFP+ to enable link.
ICX6610-48P Router(config-mif-1/3/1-1/3/8)#write mem
Write startup-config done.
- Next, configure all 48 RJ45 ports on the switch to have Active 802.3af/at PoE enabled. Otherwise, they will just act as unpowered ports.
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#interface ethernet 1/1/1 to 1/1/48
ICX6610-48P Router(config-mif-1/1/1-1/1/48)#inline power
ICX6610-48P Router(config-mif-1/1/1-1/1/48)#write mem
- Also, disable legacy PoE as it can accidentally enable and fry devices sometimes, since it's based on resistance over pairs of wires
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#stack unit 1
ICX6610-48P Router(config-unit-1)#no legacy-inline-power
ICX6610-48P Router(config-unit-1)#write mem
- PoE power status can be seen with
show inline power
orshow inline power detail
orshow inline power detail 1/1/5
for a specific device
TODO add printouts
Networking Setup
- TODO
- Tagged/trunk port
- Untagged port VLAN assignment
- 802.3ad LACP link aggregation https://fohdeesha.com/docs/icx6xxx-adv.html
- Link Aggregation
- Create a LAG with
lag <lagname> dynamic
and that will enter into the configuration for the new LAG. Name itnetpower
for the two 10G links to the Netpower on the roof of Olmsted - Add ports to the LAG, in this case the two 10G SFP+ ports
ports ethernet 1/3/1 ethernet 1/3/2
- Specify the primary port with
primary-port 1/3/1
. NOTE that all future configurations applied to 1/3/1 will auto-apply to the other members in the LAG, such as tagging it with a VLANtag interface ethernet 1/3/1
- Deploy the LAG with
deploy
- Check the status of the deployed LAG with
show lag
and look for theOpe
output column. If it shows asOpe
that means it's operational, otherwise it might showErr
orBlo
for error/blocked
- Create a LAG with
Common Commands
- More commands can be found in the Ruckus FastIron Command Reference PDF, a 1300-page monster. A free Ruckus account is needed to download (or ask JohnB)
-
?
at any point will list the commands available - The Tab key can auto-complete commands
device(config)#show li
license Show software license information
link-error-disable Link Debouncing Control
link-keepalive Link Layer Keepalive
- Immediately after logging in, the switch will be in User EXEC mode, which is read-only and has limited diagnostic commands available (ping, traceroute). To access more commands, enter into Privileged EXEC mode with
enable
. The prompt will change from>
to#
to indicate this state change.
ICX6610-48P Router>enable
ICX6610-48P Router#
- Global Configuration Mode is needed to actually make changes to the switch's ports and overall system settings. This can be done after running
enable
by following up withconfigure terminal
or a shortened version,conf t
. The prompt will change to include(config)
to indicate the mode
ICX6610-48P Router>enable
ICX6610-48P Router#configure terminal
ICX6610-48P Router(config)#
-
write memory
or the shortenedwrite mem
is needed to save the settings applied as permanent. Otherwise, a reboot will wipe any modified settings. The command may or may not output a status line
ICX6610-48P Router(config)#write memory
ICX6610-48P Router(config)#Flash Memory Write <8192 bytes per dot> .
Copy Done.
ICX6610-48P Router(config)#
-
show run
will show all the current settings on the switch, similar to/export
on Mikrotik.
ICX6610-48P Router(config)#show run
Current configuration:
!
ver 08.0.30uT7f3
!
stack unit 1st
module 1 icx6610-48p-poe-port-management-module
module 2 icx6610-qsfp-10-port-160g-module
module 3 icx6610-8-port-10g-dual-mode-module
stack disable
!
!
!
!
vlan 1 name DEFAULT-VLAN by portv
router-interface ve 1
!
<continues>
- Configure a specific port with the
interface ethernet X/Y/Z
command, or multiple ports with theinterface ethernet X/Y/Z to A/B/C
command
device(config)# interface ethernet 1/1/1
device(config-if-e1000-1/1/1)#
device(config)# interface ethernet 1/1/1 to 1/1/48
device(config-mif-1/1/1-1/1/48)#
- Adding
no
before a command will remove all configuration related to it. For example, runningno interface ethernet 1/1/1
will reset its configuration - To see fan and temperature status,
show chassis
can be used
- To see port flapping or other events, the system log can be accessed with
show log
- To name a port to describe its use, first select it and then use
port-name <someName>
interface ethernet 1/3/1
port-name netpower-primary
write mem
- See a shortened version of all the interfaces with
show interface brief
or specify a specific interface after to see just that one, sayshow interfaces brief ethernet 1/3/1
- Enable dual-mode tagged and untagged VLAN port behavior with
dual-mode
. Pass in a VLAN ID to automatically tag all untagged traffic as the VLAN ID (PVID).show interfaces brief
will show the PVID for the interfaces, as well as if it's tagged. The PVID will be removed if tagged traffic is added, by default- https://docs.ruckuswireless.com/fastiron/08.0.60/fastiron-08060-l2guide/GUID-9B341D5A-7576-41BA-AC85-F75F9340A0A7.html
- Show bandwidth information for a given port with
show statistics ethernet 1/3/2
- Show information about an SFP optic with
show optic 1/3/1
Web UI
- TODO
Port & Interface IDs
Brocade, Cisco, Juniper, and others use the X/Y/Z format to identify the different interfaces in a switch.
- X identifies the stack unit, which would only be something other than 1 when there are multiple switches combined in a switch stack. This setup is not used in the Mesh.
- Y is used to identify the slot or module within a given switch. If a switch has modular ports, say an optional 10G module, the slot number would be different. The base ports are typically 1, and then the other modules are 2, 3, etc.
- Z is used to identify the specific port in a given module. In a 24 port switch, this would go up to 24
For the ICX6610, the IDs are as follows
- The RJ45 ports on the front are numbered 1 thru 48. They exist in module 1. Their IDs are thus 1/1/1 through 1/1/48.
- The 10G ports on the left front of the switch are numbered 1 thru 8. They exist in module 3. Their IDs are thus 1/3/1 through 1/3/8
- The 40G ports on the back of the switch are numbered 1 thru 8. They exist in module 2. The 40G-only ports are 1/2/1 and 1/2/6 and are closest to the console port. NOTE that the 40G-only ports will not operate in breakout mode, nor will they operate at 10G. The breakout-only ports are 1/2/2 thru 1/2/5 for the top port, and 1/2/7 thru 1/2/10 for the bottom port. These breakout ports are closest to the fan. NOTE that the breakout ports will not operate at 40G, and will only work as four 10G links
Console Cable
This was JohnB's first time needing to use a console cable to set up a device, so this section serves to familiarize a newcomer with the process.
Many IT devices such as APC UPS battery backups, Cisco switches, and Ubiquiti gear have an RJ45 port labeled "Console" that can be used to configure or talk to the device. In some cases, configuration must occur with this method before more convenient configuration methods such as SSH or a Web UI are available. These RJ45 ports can have different wiring methods, so an APC RJ45 to DB9 cable is electrically different from a Cisco RJ45 to DB9 cable.
A normal serial adapter (say a Raspberry Pi or an ESP8266 or Arduino or ESP32) will only work with 3.3V or 5V logic, and will be incompatible with the 12V signals needed to talk to the networking devices. A specific adapter cable is needed. Because the RJ45 wiring can be different depending on the manufacturer, it's better to get a USB to DB9 cable than a USB to RJ45 cable. The Eaton/Tripp Lite Keyspan adapter is the OG, but cheaper options with the Prolific PL2303 chip work fine as well (USB-A option or the USB-C option JohnB got).
Once the cable is plugged into a computer, it should show up in USB Devices or Device Manager, but it may not be immediately ready to use. JohnB got hung up on a Macbook Pro M1 running macOS 14.3 where the device showed up in System Report but was not showing up as a serial connection. As per the instructions, ls -ltr /dev/*usb*
was supposed to show the device, but there were no matches. There might have been an issue with kext Kernel Extensions and the installer provided on the websites (Prolific driver, Cable Matters driver(SKU 201060), they're the same). What ended up working was to install the driver via the App Store. After that, the device showed up as /dev/tty.PL2303G-USBtoUART110
and /dev/cu.PL2303G-USBtoUART110
. What's the difference? TTY devices are for calling into UNIX systems, whereas CU (Call-Up) devices are for calling out from them (eg, modems), so /dev/cu.*
is the correct device to use
Now the connection can be made. Connect the RJ45 to DB9 cable of choice (the blue Cisco cable works fine for the Brocade switch) and plug it in to the console port on the switch. Plug in the USB end. The screen
Terminal command works and is installed by default, and the console session can be started with screen /dev/cu.PL2303G-USBtoUART110 9600
where 9600 is the baud rate in bits per second (9600 is pretty universal). Power cycle the switch and it should immediately start outputting content. For example:
ICX Boot Code Version 10.1.00 (grz10100)
Enter 'a' to stop at memory test
Enter 'b' to stop at boot monitor
BOOT INFO: load monitor from boot flash, cksum = 71f1
BOOT INFO: verify flash files.........
BOOT INFO: load image from primary copy...
platform type = 12
PCIE-1 LTSSM status: 22
PCIE Switch status: 0
..............................
Firmware integrity checksum passed
JohnB found that backspace did not work, and a mis-type would require pushing ENTER
to finish the command or CTRL
+ C
to clear the line.
An alternative to screen
is minicom
which is recommended by some people. Minicom can be installed on macOS with Homebrew, for example brew install minicom
. JohnB has yet to set up minicom so a TODO is to finish this section with usage details on Minicom. Thishas some good information
TFTP Setup
To update the software of the Brocade switch, a TFTP server needs to be running on the same network as the switch. This ServeTheHome user set up a websitewith detailed instructions.
JohnB's abbreviated TFTP setup notes are:
- Install Linux Mint (Ubuntu base)
-
Download the firmware files and extract them in the home directory. In this case, the files are in
/home/test/brocade-12-19-2023/
- Modify the permissions download directory with
chmod --recursive 777 /home/test/brocade-12-19-2023/
, otherwise Permission Denied errors might show up - Install TFTP server with
sudo apt install tftpd-hpa
- Modify TFTP server settings with
nano /etc/default/tftpd-hpa
to match the following lines. This will remove the username, set the root directory to serve as the TFTP-Content directory from the earlier extract, serve TFTP on port 69, and print extra information in the logs
TFTP_USERNAME="nobody"
TFTP_DIRECTORY="/home/test/brocade-12-19-2023/TFTP-Content"
TFTP_ADDRESS="0.0.0.0:69"
TFTP_OPTIONS="--secure -vvvv"
- Restart the service with
systemctl restart tftpd-hpa
to apply the settings - (Optional) Monitor the TFTP server's activity with
tail -F /var/log/syslog
. This will show connection attempts, errors, transferred files, and more - (Optional) Test the TFTP server functionality with another computer. Assuming the TFTP server's IP is 10.1.1.2, use another computer and follow these instructions
- Connect to the TFTP server with
tftp 10.1.1.2
and it should connect, dropping into atftp >
prompt - Try to get a file with
get ICX6610-FCX/grz10100.bin
and it should copy it to the current working directory - Exit the TFTP prompt with
quit
- Connect to the TFTP server with
Resources
-
ServeTheHome forum thread where johnb found out about these https://forums.servethehome.com/index.php?threads/brocade-icx-series-cheap-powerful-10gbe-40gbe-switching.21107/
-
Useful info on Console/Serial cables, Screen, Minicom https://pbxbook.com/other/mac-tty.html
-
USB-C to Serial/DB9/Console cable with Prolific PL2303 chip https://www.amazon.com/Cable-Matters-Serial-Adapter-USB-C/dp/B075GV6VL1 (SKU 201060). macOS App Store driver https://apps.apple.com/us/app/pl2303-serial/id1624835354?mt=12
-
Fohdeesha TFTP and Brocade firmware setup https://fohdeesha.com/docs/brocade-overview.html
-
Fohdeesha ICX6610 firmware updating and initial configuration https://fohdeesha.com/docs/fcx.html
-
Fohdeesha ICX6610 SSH setup, DNS, NTP, PoE, etc https://fohdeesha.com/docs/icx6xxx-adv.html
-
Fohdeesha ICX6610 10G license unlocking https://fohdeesha.com/docs/6610.html
-
Youtube version of the setup process https://www.youtube.com/watch?v=yutgXiGZ4Y8
-
Mesh IP Network Number allocation (strategy 3, split the network number into two parts so NN584 becomes 10.69.5.84) https://wiki.mesh.nycmesh.net/link/94
-
Mesh Omni config generator, which gives some information on CIDR, IP, etc https://configgen.nycmesh.net/?version=v4.9&device=Omnitik5AC&template=omni-poe-ether5.rsc.tmpl
-
Mesh Juniper vs Mikrotik configuration detail https://wiki.mesh.nycmesh.net/link/127
2024/03/12 Notes
-
show ip interface
to get output about the virtual interfaces attached to VLANs
SSH@nycmesh-nn584-brocade-poe-switch#show ip interface
Interface IP-Address OK? Method Status Protocol VRF
Ve 1 10.69.5.84 YES manual up up default-vrf
10.97.227.165
Ve 10 10.10.10.10 YES manual up up default-vrf
- once entered into a VLAN, say with
vlan 11
then runningno untagged ethernet 1/2/6
would remove the interface from that VLAN. Theshow interfaces brief
should show the PVID to have changed to the VLAN ID if the ports were set to untagged - Then create a virtual interface to go with that VLAN, say
interface ve 11
and then add an IP/network to it withip address 10.70.196.1/23
- Create a DHCP pool with
ip dhcp-server pool meshbridge
which does not yet have an address space or network associated with it. Set the network withnetwork 10.96.146.0/26
and then set the first section of the range as excluded withexcluded-address 10.96.146.1 10.96.146.10
. Thenshow run
should show the configured DHCP server info:
ip dhcp-server pool meshbridge
excluded-address 10.96.146.1 10.96.146.10
lease 1 0 0
network 10.96.146.0 255.255.255.192
!